# MCSA can miss a fault if the speed is wrong: what a 2021 industrial review found

What is motor current signature analysis, and why does it need an accurate speed? A 2021 Sensors review opens with a 90 kW pump motor where a 3 rpm error turned healthy harmonics into 'broken bars', then tests speed estimation on 79 motors. What it found, and what it does not say.

Here is a situation we'll use as an illustration. It is invented, not a reported case. A reliability technician clamps a current probe on the feeder of a pump motor and records a stator current spectrum. The software looks in a narrow window where a broken-rotor-bar sideband should sit, finds a peak and reports "possible rotor damage". The window was placed using a speed that was estimated, because there is no speed sensor on the motor and nobody can reach the shaft. The estimate was a few rpm out, so the peak in the window is a healthy harmonic from the load, and the real sideband, if there is one, is somewhere the software did not look. The report goes into the file as a rotor finding, or, if the opposite happens, as "no fault found".

This post is about that gap. It comes from a 2021 open-access review in *Sensors* by Bonet-Jara, Quijano-Lopez, Morinigo-Sotelo and Pons-Llinares, "Sensorless Speed Estimation for the Diagnosis of Induction Motors via MCSA. Review and Commercial Devices Analysis". The paper opens with a real industrial case, reviews the families of sensorless speed estimation methods, and tests the approach used by two leading commercial diagnostic devices on measurements from 79 industrial induction motors. We read the whole paper. Every quotation below is checked against the PDF, with section and page.

**Short answer:** Motor current signature analysis (MCSA) looks for fault harmonics in the stator current spectrum, and their position depends on motor speed. If the speed estimate is off by a few rpm, the search can land on a healthy harmonic (false positive) or miss the real one (false negative). The authors call accurate speed estimation vital.

## What is motor current signature analysis?

In this paper, MCSA is a method mainly applied to detect speed-dependent fault harmonics in the frequency spectrum of the stator current of an induction motor (Section 1, p. 2). The faults it uses as examples are rotor bar breakage and eccentricities, which "induce speed-dependent harmonics in the stator current" (Section 2, p. 3). The measurement is not intrusive: the paper notes that current sensing "can be done in a non-invasive way using current clamps" (Section 3.4, p. 8).

The reading works in three steps, as the paper describes them for rotor bars (Section 2, pp. 3-4):

1. The fundamental frequency (the supply frequency) is the highest peak in the spectrum, so it is easy to find.
2. If the speed is known or estimated, "the slip (s) can be determined and with it the position of these harmonics."
3. The harmonic found at that position is measured in decibels against criteria. The paper uses one example criterion throughout: below -48 dB the motor is considered healthy, between -48 and -36 dB there might be one or several broken or cracked bars, and above -36 dB there are multiple broken bars.

The paper stresses that these thresholds are "empirically obtained limits", that commercial devices use slightly different ones, and that the exact value is secondary to its argument: "given a failure criterion, a small error in speed estimation can lead to a wrong diagnosis" (Section 2, p. 4). We use the same thresholds here only to follow the paper's examples; they are not a standard.

## Why does MCSA need an accurate speed estimate?

Because the speed decides where to look. The authors give two reasons the speed estimate matters. First, "in order to extract and quantify these harmonics, a good speed estimation is previously needed to accurately determine their position". Second, "most industrial motors are neither coupled to physical speed sensors nor do they have the shaft accessible to perform manual measurements" (Section 1, p. 1). Elsewhere they say that "speed sensors are rarely present in industrial environments" (Section 1, p. 2).

So the speed is estimated, and the estimate sets the search. The paper describes how both commercial devices it analyses work: they "estimate the speed to approximately calculate the position in the spectrum of the faulty harmonic frequency, set a search frequency band around it, and finally calculate the maximum amplitude harmonic inside" (Section 5, p. 13). The authors then spell out why the quality of that window matters:

- If the speed estimate is very accurate, the window can be narrow enough "to prevent other significant healthy harmonics from entering it (reducing false positives)".
- A good estimate also ensures the window "will contain the fault harmonic frequency (reducing false negatives)" (Section 5, p. 13).

A poor estimate does the reverse. A window centred in the wrong place can admit a healthy harmonic, or can miss the fault harmonic altogether.

The paper also warns about a shortcut. Many research papers, it says, test lab motors under perfectly known conditions but analyse the expected frequency band "assuming that the highest peak of the band will be the fault harmonic". In a real plant, it calls these "dangerous strategies", because healthy-state harmonics "can show frequencies very close to those of healthy state caused by multiple factors (winding harmonics, load oscillations, gear boxes, etc.), and be confused with them" (Section 1, p. 2).

## What did the industrial case show?

The paper's opening example is a real measurement: the stator current of a two-pole motor of 90 kW "driving a submerged pump" (the paper writes IM for induction motor), analysed with the FFT (Section 2, p. 4). The authors report that "a deviation of only 3 rpm means to identify two healthy state harmonics (marked with green diamonds) as two broken bar harmonics (marked with red circles)" (Figure 1a, Section 2, p. 4).

The diamonds belong to the healthy state, the authors say, because they do not satisfy any of the formulas for rotor electrical asymmetries, rotor-stator misalignments or stator electrical asymmetries. Zooming out (Figure 1b) shows a smearing effect around the fundamental and several sets of sideband harmonics not predicted by the fault formulas. The authors link these to the load: "as stated in [18], these effects are usually related to the operation with gear boxes and/or load oscillations" (Section 2, p. 4). The conclusion they draw: the error "leads to diagnose the motor as faulty" when the broken-bar harmonics are actually in the healthy zone.

Two points follow from this case.

- **The error needed is small.** The paper repeats it later: "As shown in Section 2, only an error of 3 rpm is enough to issue a false positive. Moreover, if the motor is also working with load oscillations, the error needed to commit a mistake is even lower" (Section 3.4, p. 8).
- **Taking the biggest peak in the band fails here.** The authors say the approach of locating the fault harmonic as the maximum in its possible operating band "relies on the fact that no other significant harmonic will be present in the search band", and that, as this case shows, "that does not always hold true, and therefore, it can be a source of false positives" (Section 2, p. 5).

![Ink line drawing of a squirrel-cage induction motor on a baseplate, with a clamp-on current probe closed around one of three cables running into a motor control cabinet](/blog/media/what-is-motor-current-signature-analysis-speed-estimation-mwzxnr7s.webp)

## Can a wrong speed also hide a real fault?

The abstract names both directions: accurate speed estimation is needed to "prevent false positives and false negatives". The false negative in the paper comes from the second part of the review, where the authors tested one of the two commercial devices (the Megger EXP4000) on two industrial motors and compared it with a rotor-slot-harmonic (RSH) algorithm that was given the number of rotor bars (Section 5.1.2, pp. 16-18).

- **Four-pole 1500 kW motor.** The EXP4000 "was able to diagnose satisfactorily": its error in placing the lower sideband harmonic (0.039 Hz) was the same size as the frequency resolution (0.039 Hz).
- **Six-pole 800 kW motor.** The device "delivered a false negative". Its deviation was 0.566 Hz, "16 times bigger than the frequency resolution" of 0.036 Hz. The authors note that this corresponded to an error of only 0.09 Hz in the estimated mixed eccentricity harmonic, and suggest a possible "harmonic misidentification", since that harmonic had an amplitude above the noise level of "less than 6 dB" in the line current spectrum (p. 18).
- **The RSH algorithm** placed the harmonic within 0.005 Hz and 0.003 Hz in the two motors, which the authors say was 7 and 11 times smaller than the frequency resolution, "thereby issuing a correct diagnosis" (p. 18).

Why does a small frequency error turn into a large positioning error? The paper's explanation is bandwidth. The mixed eccentricity harmonics that the commercial EXP4000 uses "only vary a few fractions of hertz over its normal operating range. Therefore, a small error in the estimation of their frequencies implies a large error in the estimation of the speed" (Section 4.3, p. 12). For a capture time of 25 s, which the authors call industry standard, the largest frequency resolution error is 0.02 Hz; the error in the fault harmonic frequency is then "3, 7, or 11 times bigger" for the lower mixed eccentricity harmonic, depending on the number of poles (Section 5.1.2, p. 17).

The authors also point to a second source of error that anyone who has taken a spectrum will recognise: the frequency resolution depends on how long the record is. In the paper's words, "the longer the capture time is, the better the resolution" (Section 4.2, p. 11).

## How hard is it to get speed without a speed sensor?

The paper groups sensorless speed estimation methods into families, and for each says how it fits MCSA. The summary below follows Sections 3, 4 and 4.3 (pp. 5-12).

| Family | What it needs | What the paper says about using it with MCSA |
|---|---|---|
| Fundamental-model methods (observers, adaptive systems, with or without AI) | Voltage and current signals, plus identification of motor parameters | Built for control, not diagnosis. Voltage sensing "requires the motor to be stopped" to attach probes safely. Errors of a few rpm may do for control but "this might not hold true for MCSA, especially at low slips". May suit continuous monitoring built into the drive; the authors say that still needs study |
| Signal-injection methods | A high-frequency signal added to the supply | Developed for zero and very low speed. Judged unsuitable for MCSA: "the robustness gained does not compensate for their excessive complexity of implementation" |
| Slotting and eccentricity harmonics: mixed eccentricity harmonics | Only the number of poles, which is on the nameplate | The preferred method in commercial devices. Narrow bandwidth, so small frequency errors become large speed errors. Can be hard to detect, especially in two-pole motors |
| Slotting and eccentricity harmonics: rotor slot harmonics | The number of rotor slots, "a machine characteristic that is rarely known by the motor owner" | The most accurate: "errors can be less than 0.1 rpm". But the authors found no reliable automatic, non-invasive way to get the rotor slot count, which limits use outside the laboratory |

The paper's overall judgement is in the conclusion: "SSE in diagnostic procedures is not a solved issue" (Section 1, p. 3), and the scientific community "has yet to provide a precise, automatic and general method that helps to achieve a highly reliable MCSA-based online condition monitoring system for the modern industry" (Section 6, pp. 26-27).

## What did 79 industrial motors show?

The second half of the paper tests speed estimation on a database of 79 industrial induction motors, recorded with high-resolution equipment. Appendix A says the database comes from "several years of consulting work with different types of industry" and includes motors driving "vertical/horizontal pumps, conveyors, compressors, worm gears, shredders, etc." (p. 28). Some of the findings:

- **Mixed eccentricity harmonic detectability (EXP4000 approach).** In 48.10% of the 79 cases, a higher harmonic than the upper mixed eccentricity harmonic was present in the search band. The same proportion (48.10%) applied to the lower one. For the lower one, the authors say the majority of these motors were two-pole machines (Section 5.1.1, p. 15).
- **Search window misses (MCEMAX-type approach).** Using a replica of the PdMA MCEMAX algorithm, the actual broken-bar harmonic was outside the search window in 36.71% of cases and the mixed eccentricity harmonic in 32.91% (Section 5.2.1, p. 20). The authors trace this to the preliminary speed estimate from nameplate data: the rated slip on a nameplate can be up to 20% out, because the paper notes that a tolerance of up to 20% on the rated slip is allowed for motors above 1 kW (Section 5.2.1, p. 19).
- **Speed errors above 0.5 rpm.** Even when the window was perfectly centred on the broken-bar harmonic, the speed error was above 0.5 rpm for 18.99% of the motors. For the mixed eccentricity harmonic it was 29.11% (Sections 5.2.2, 5.2.3 and 5.3, pp. 22-24).
- **What happens when the speed estimate fails.** The MCEMAX device, the paper says, "asks the user to estimate speed manually" when its two peaks are not found or do not match (Section 5.2, p. 19). In the authors' words, commercial devices "need human intervention to double-check the diagnostic due to the lack of reliability" (Section 2, p. 5).
- **Rotor-slot-harmonic algorithms did better,** where the number of rotor bars was known. The authors state they "outperform" the replicas of the two commercial algorithms, but add that the lack of an automatic way to get the rotor bar count "prevents its use in industrial devices" (Section 5.3, p. 25).

The authors are fair to the devices. They write: "it is fair to mention that, despite the weaknesses highlighted in this section, MCEMAX and EXP4000 are still powerful and user-friendly tools that can be useful in certain conditions to assess rotor bars or eccentricity" (Section 5.3, p. 25).

![Ink line drawing of three different motor-driven machines, a vertical pump, a conveyor with a worm gearbox and a compressor, each with its own electric motor and cable run to a shared electrical cabinet](/blog/media/what-is-motor-current-signature-analysis-speed-estimation-mwzxo7zg.webp)

## What should a reliability team ask before trusting a spectrum finding?

The paper does not give a checklist. The questions below are ours, built on what it reports, and are not taken from it.

1. **How was the speed obtained?** Measured on the shaft, estimated by the device from the spectrum, or approximated from the nameplate and the current level? The paper shows that the last of these can put the search window in the wrong place.
2. **How long was the capture, and what is the frequency resolution?** The paper gives the maximum resolution error as half of one over the capture time. A 25 s capture gives 0.02 Hz, per its own example.
3. **Where was the search window, and how wide?** A finding that is simply the biggest peak in the window depends on what else is in the window.
4. **Is there a reason for healthy sidebands near the fault frequency?** The paper's industrial case had gearbox and load-oscillation effects. It also says reliability "is further reduced when the motor works in the presence of load oscillations and is fed by a frequency converter" (Section 2, p. 5). For motors on drives, our post on [VFD overcurrent causes](https://hangersearch.com/blog/vfd-overcurrent-fault-causes) covers the drive side.
5. **Was the result double-checked by a person?** The paper's finding is that the commercial devices it analysed still need that.

Two more points follow from the paper's argument. A finding is a claim about a frequency position, and it is only as good as the speed behind it. And a negative result carries the same dependence on speed as a positive one.

## What does this review mean for the records you keep?

A spectrum screenshot without the speed it was read at is hard to check later. If the same motor is measured again next year, the new reading is only comparable if the earlier one says how the speed was obtained, how long the capture was and what window was used. That is a records problem as much as a signal-processing one. For how condition data fits into maintenance strategy, see [predictive vs preventive vs condition-based maintenance](https://hangersearch.com/blog/predictive-vs-preventive-vs-condition-based-maintenance) and the explainer on a [power-industry review of predictive maintenance](https://hangersearch.com/blog/what-is-predictive-maintenance-power-industry-review). We also covered another review that warns against assuming a method generalises: [bearing vibration methods are not one-size-fits-all](https://hangersearch.com/blog/vibration-analysis-of-bearings-review).

## What this review doesn't tell you

- **It is not a verdict on MCSA.** The paper's subject is speed estimation, one step in MCSA. The authors say it is "vital" and that existing methods "either do not provide enough precision for this purpose or have limited applicability"; they do not say MCSA does not work.
- **The percentages are about speed and search windows,** not about how many motors were misdiagnosed. The paper does not report a false-positive or false-negative rate for the 79 motors, and the text we read does not say the motors were opened to confirm faults.
- **Some commercial-algorithm results come from replicas.** For MCEMAX the authors replicated the algorithm; for the EXP4000 two-motor comparison the current was captured with the device and re-analysed. The 79 recordings were made with high-resolution oscilloscopes and current probes, not the devices' own front ends, so the authors could "focus only on the characteristics of each SSE algorithm" (Section 5, p. 13).
- **The database is the authors' own,** from consulting work, and they describe it as a robust statistical sample. It is not a random sample of all plants.
- **It is a 2021 review.** Newer work was not read for this post. The abstract says no earlier review of this topic had been published.
- **Broken rotor bars are only an example here.** This post stays on the speed problem; it does not review rotor-bar detection methods.
- **We did not use the paper's tables,** whose values were not extracted cleanly from the PDF. Every number above is from the text.

## Where does HangerSearch fit?

HangerSearch does not perform MCSA, estimate motor speed or diagnose faults. It is a private search engine for engineering report archives. If your motor test reports and inspection reports sit as finalized PDFs, HangerSearch can search them and cite the page each answer comes from, so the earlier report on a motor can be found when the same motor is measured again. See [how we handle your reports](https://hangersearch.com/trust).

Book a 20-minute demo: hangersearch.com

## FAQ

**What is motor current signature analysis?**
Motor current signature analysis (MCSA) is a method, mainly applied to induction motors, that looks for speed-dependent fault harmonics in the frequency spectrum of the stator current. The paper's examples are rotor bar breakage and eccentricity. Current can be sensed non-invasively with clamps.

**Why does MCSA need an accurate speed estimate?**
The position of a fault harmonic in the spectrum depends on slip, and so on speed. A speed error of only 3 rpm was enough, in the paper's industrial case on a 90 kW two-pole motor, for healthy harmonics to be identified as broken-bar harmonics. Accurate speed estimation reduces both false positives and false negatives.

**Can a wrong speed estimate cause a false negative as well as a false positive?**
Yes, according to the paper. In one of its two commercial-device examples, a six-pole 800 kW motor, the device "delivered a false negative" because the fault harmonic was placed 0.566 Hz away from where it actually was.

**Do you need a speed sensor to do MCSA?**
Not necessarily, but the paper notes most industrial motors have none and the shaft is rarely accessible. The speed is then estimated. The authors review the methods and conclude that none yet gives accurate, automatic estimation for any motor, with the rotor slot harmonic approach the most accurate but requiring the rotor slot count.

**Is the highest peak in the expected band the fault?**
Not reliably. The paper calls that assumption dangerous in real industrial environments, because healthy harmonics from winding effects, load oscillations or gearboxes can sit very close to the fault harmonic frequency.

## Sources

1. Bonet-Jara, J., Quijano-Lopez, A., Morinigo-Sotelo, D. and Pons-Llinares, J. (2021). "Sensorless Speed Estimation for the Diagnosis of Induction Motors via MCSA. Review and Commercial Devices Analysis." *Sensors* 21(15): 5037. https://doi.org/10.3390/s21155037. Open access (CC BY). Published 25 July 2021; authors at the Universitat Politecnica de Valencia and the University of Valladolid. Read in full (35 pages); page numbers in this post are the PDF's "N of 35" page numbers.

## Related

- [Predictive vs preventive vs condition-based maintenance: the difference in practice](https://hangersearch.com/blog/predictive-vs-preventive-vs-condition-based-maintenance)
- [From corrective to predictive maintenance: what a 2023 power-industry review actually covers](https://hangersearch.com/blog/what-is-predictive-maintenance-power-industry-review)
- [Bearing vibration methods are not one-size-fits-all: what a 2021 review concluded](https://hangersearch.com/blog/vibration-analysis-of-bearings-review)
- [VFD overcurrent fault causes](https://hangersearch.com/blog/vfd-overcurrent-fault-causes)
- [How HangerSearch handles your data](https://hangersearch.com/trust)